DAF 95XF УКАЗАТЕЛИ и сигнальные лампы


4. DIRECTION INDICATORS AND WARNING LIGHTS
WARNING LIGHTS

A supply voltage is applied to connection point 6
of warning-light switch C765 through fuse E108.
By activating the warning light/direction indicator
switch the supply voltage is applied to point 37 of
the CTE-2.
The CTE 2 now supplies a square-block voltage
through point 4 to lights C014, C016 and C018 (all
on the left side) and through point 31 to C015,
C017 and C019 (all on the right side), as a result
of which these lights start blinking simultaneously.
The warning lights also function if the contact is
not activated.
CTE-2 (point 35) also supplies a square-block
voltage to warning light/direction indicator switch
C765 ( to point 1), causing the LED in the switch
to blink also.
DIRECTION INDICATORS
Left
If the direction indicator switch (C775) is activated
to the left (connection between points 3 and 2),
the supply voltage is passed on to point 53 of the
CTE-2 through wire 2002. Subsequently the
CTE-2 supplies a square-wave signal through
point 4 to C014, C016 and C018 (left direction
indicators) and through point 2 to connector
socket A000 pin 3 (in the case of an FA) or A002
pin 3 (in the case of an FT). Every time a pulse is
supplied to point 4 of the CTE-2, the lights will
blink briefly.
Right
If the direction indicator switch (C775) is activated
to the right (connection between points 3 and 1),
the supply voltage is passed on to point 24 of the
CTE-2 through wire 2001.
Subsequently the CTE-2 supplies a square-wave
signal through point 31 to C015, C017 and C019
(right direction indicators) and through point 30 to
connector socket A000 pin 5 (in the case of an
FA) or A002 pin 5 (in the case of an FT). Every
time a pulse is supplied to point 31 of the CTE-2,
the lights will blink briefly.
The CTE-2 (points 7 and 34) also supplies a
signal to the instrument panel.
If the direction indicator installation functions
properly, the lights for the truck (2/202) and the
trailer (8/202) will light up.

VARIANTS
Location
29,37,38,43,42 Connector 495 is only used in
the case of an FA. Connector
493 is used in the case of an
FT.
44 Connector A000 is used for
an FA, connector A002 for an
FT.
SEE THE SYSTEM MANUAL FOR MORE
INFORMATION